EasyManua.ls Logo

FAAC E145S - Mains Power Supply Connection

FAAC E145S
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E145S 12 532369 - Rev.A
Translation of the original instructions
ENGLISH
MOTORS
J12
LAMP
M1 M2
M M
1 2 3 4 5 6 7 8
COM
OP
CL
COM
OP
CL
C C
COM Motor COMMON contact
OP PHASE to open the electric motor
CL PHASE to close the electric motor
C Thrust capacitor
For single operator installations, connect the motor
to terminals M1.
For double operator installations, connect:
- the motor that opens first to terminals M1
- the motor that closes first to terminals M2
!
The operators MUST be connected to the earth of the
electrical system.
MAINS POWER SUPPLY
F
Carry out the following operations with the power
supply disconnected.
LOCK
MAIN
LAMP
M1 M2 IN1 IN2 IN3 IN4 IN5
F+/R1 -/R2
M M
230V~
60W max
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 27 28 29
23
24
25
26
RADIO
RP/DEC
2EASY
CONNECTIVITY
CR2032
USB-A
EDGE1
OUT1
COM
OP
CL
PE
N
L
COM
OP-A
+24V
+24V
-
-
-
-
OP-B
STOP
FSW CL
FSW OP
OP
CL
OUT2
LOCK1
LOCK2
EDGE2
FCC2
FCA2
FCC1
FCA1
230V~
C C
J1
F10 A
F1
Connect the Phase (L) and Neutral (N) to the 230 V~
power supply.
The board has a 10 A fuse on the Phase.
Connect the earth of the electrical system to terminal
PE.

Table of Contents