E145S 24 532369 - Rev.A
DL1
DL2
DL3
DL1
DL2
DL3
S800H ENC
2EASY
SAFEcoder
2EASY
DL1
DL2
DL3
DL1
DL2
DL3
4
DL1 DL1
DL1
DL2
DL3
DL1
DL2
DL3
MOT1MOT2
DL1
DL2
DL3
DL1
DL2
DL3
MOT2MOT1
5
Translation of the original instructions
ENGLISH
that the automation operates according to the
type of sensitive edge installed.
6 Addressing Sensitive Edges
Key: 0=OFF , 1=ON
1 1 0 1 CL EDGE
0 1 1 0 OP EDGE
BUS 2EASY ENCODER
1. Connect the cables of the encoder to the 2EASY
terminal board.
2. After turning on power to the board, check the
LEDs on each encoder with the leaf stationary:
DL1 lit = encoder powered
DL2 lit = encoder connected to MOTOR1
DL2 off = encoder connected to MOTOR2
i
For each encoder that does not appear to be con-
nected to the correct leaf, temporarily disconnect
the power supply and invert the 2 wires on the 2EASY
terminal board.
3. Register the devices (see specific section).
4. Check the BUS 2easy devices(see specific section).
ON
1 2 3 4
DL2 on = encoder connected to MOT1
DL2 off = encoder connected to MOT2
Correct connections