E145S 26 532369 - Rev.A
Translation of the original instructions
ENGLISH
CHECKING THE BUS 2EASY DEVICES
1. Select parameter bu in basic programming. If
there are no devices registered,
no will appear
on the display, otherwise segment 13 will be lit.
This menu can be used to check the operation of
the registered devices: activate each device and
check that the corresponding segment lights up
(6).
2. Press and hold the
++ button and keep it pressed;
the segments relative to the registered devices
will come on. Each segment of the display cor-
responds to a type of device:
8.5 XF RADIO MODULE
E145S is fitted with an OMNIDEC integrated two
channel decoding system that can memorise, via the
XF radio module, FAAC radio controls that use the
following types of radio code: SLH/SLH LR, LC/RC, DS.
i
The three types of radio codes can coexist simultane-
ously.
A maximum of 1600 codes can be memorised.
The memorised codes act as OPEN A or OPEN B/CLOSE
commands.
The radio controls and the XF radio module must have
the same frequency.
When memorising the codes, keep the radio control
approximately one meter from the XF radio module.
1. Insert the XF radio module into the J4 connector,
being careful to insert it in the right way round and
with the mains power switched off.
J4
2. Turn power on to the board.
3. Memorise the radio controls.
!
Ensure that there are no obstacles (persons or things)
while the automation is moving.
RADIO CONTROLS SLH/SLH LR
Memorise the first radio control, MASTER, on the
board. Then add other radio controls that are re-
quired following the learning procedure that doesn’t
require you to access the board.
To check if the radio control is a MASTER device, press
and hold a button and watch the LED:
- flashes briefly, then the light becomes
steady = MASTER
- turns on immediately with a steady light = NON
MASTER
i
Whenever a new master is memorised on the board,
any SLH/SLH LR radio controls that are already in
use are disabled.
Memorising the first radio control
1. On the board, press the
++ button (memorize OPEN
A) or the
--
button (memorize OPEN B/CLOSE) and
8. 8.
135
12
11
1
2
147 6 8
103 4 9
6
1 Open A control device
2 Open B control device
3 Closing photocells
4 Photocells for Open impulse
5 Opening/closing photocells
6 Close control device
7 Opening photocells
8 Stop control device
9 Closing sensitive edge
10 Encoder - leaf 2
11 Not used
12 Opening sensitive edge
13 BUS 2easy status
14 Encoder - leaf 1

Table of Contents