E145S 15 532369 - Rev.A
Translation of the original instructions
ENGLISH
Function default
bu
Learn BUS 2easy devices
See the relative section.
M2
MOTOR 2 OPERATION in dead man mode
(displayed only if
Mn = 2)
+ OPEN (displaying oP)
- CLOSE (displaying cL)
--
M1
MOTOR 1 OPERATION in dead man mode
+ OPEN (displaying oP)
- CLOSE (displaying cL)
--
tL
SETUP
See the relative section.
--
St
LEAVING THE PROGRAMMING MODE
Y exit saving the settings
no exit without saving the settings
After having confirmed using button
FF, the display
indicates the STATUS of the automation:
Y
00 CLOSED 08 CHECK Bus 2easy
01 OPEN
09 PREFLASHING BEFORE OPEN-
ING
02 STATIONARY THEN OPENS
10 PREFLASHING BEFORE CLOS-
ING
03 STATIONARY THEN CLOSES 11 EMERGENCY OPEN
04 IN PAUSE 12 EMERGENCY CLOSE
05 OPENING HP HOLD POSITION
06 CLOSING . (flashing) SLEEP
07 FAILSAFE IN PROGRESS
3 ADVANCED programming menu
Function default
bO
MAXIMUM TORQUE AT INITIAL THRUST
When it starts, the motor operates at maximum
power for the time set in this option.
01…10 (Adjustment step: 1 s)
01
cS
CLOSING THRUST
(not displayed if
FC = 1)
This function assists the closing of the electric lock:
it pushes against the closing stop with maximum
force for 2 s. DO NOT enable the function if there
is not a mechanical closing stop fitted.
no disabled
Y enabled
no
rS
REVERSE STROKE FOR OPENING
(not displayed if
FC = 1)
This function assists the release of the electric
lock: it pushes against the closing stop before
opening. DO NOT enable the function if there
is not a mechanical closing stop fitted.
no disabled
Y enabled
no
Od
LEAF OPENING DELAY
(displayed only if
Mn = 2)
The delay is applied to MOTOR 2.
Displayed in seconds up to 59, then in steps of 10 s.
00…59 (Adjustment step: 1 s)
1.0…1.3 (Adjustment step: 10 s)
02
IP
REVERSE ON OBSTACLE
This function specifies the amount the leaf is
reversed after an obstacle has been detected.
no total reverse
Y partial reverse (2 s)
no
r1
SLOWDOWN LEAF 1
(NOT displayed if
FA/FC = 2)
Specifies the deceleration space for the leaf con-
nected to MOTOR 1 (% of the total length of travel).
01…50 (Adjustment step: 1%)
20
r2
SLOWDOWN LEAF 2
(NOT displayed if
FA/FC = 2 , or if Mn = 1)
Specifies the deceleration space for the leaf con-
nected to MOTOR 2 (% of the total length of travel).
01…50 (Adjustment step: 1%)
20