E145S 14 532369 - Rev.A
Translation of the original instructions
ENGLISH
2 BASIC programming menu
Function default
C
C
SIMPLY CONNECT
To enable Simply Connect, select a communica-
tion channel:
0 disabled
1 (CH1) , 2 (CH2) , 3 (CH3) , 4 (CH4)
0
CF
TYPE OF AUTOMATION
1 swing gate
2 sliding gate
1
dF
DEFAULT CONFIGURATION
Displays
Y if the programming corresponds to the
default settings. Select
Y if you wish to reload
the default values for the type of automation.
Y the programming corresponds to the
DEFAULT settings
no the programming DOES NOT correspond to
the default settings
Y
Lo
FUNCTIONING LOGIC
E Semi-automatic
EP Semi-automatic step by step
S Automatic Safety
SA Automatic Safety 2
SP Automatic Safety Step by Step
A1 Automatic 1
A Automatic
AP Automatic Step by Step
At Automatic with Timer Function
b Semi-automatic b
bC Mixed (Impulse opening / Hold-to-run
closing)
C Hold-to-run
E
PA
PAUSE TIME
(displayed only if an automatic logic has been
selected)
Displayed in seconds up to 59, then in steps of 10 s.
0059 (Adjustment step: 1 s)
1.09.5 (Adjustment step: 10 s)
30
Pb
PARTIAL PAUSE TIME
(displayed only if an automatic logic has been
selected)
Carried out after partial opening.
Displayed in seconds up to 59, then in steps of 10 s.
0059 (Adjustment step: 1 s)
1.09.5 (Adjustment step: 10 s)
30
Mn
NUMBER of MOTORS connected
1 1 motor
2 2 motors
2
Function default
F1
MOTOR 1 POWER
0150 (levels; 50 =maximum power)
25
F2
MOTOR 2 POWER
(displayed only if
Mn = 2)
0150 (levels; 50 =maximum power)
25
En
ENCODER
Enables/disables the encoder on both motors.
no disabled
Y enabled
no
FA
OPENING LIMIT SWITCH
(displayed only if
CF = 1)
Enables/disables the opening limit switches, to
stop the automation or start the slowdown. Mod-
ifying the value requires a new SETUP.
no disabled
01 stop
02 start slowdown
no
FC
CLOSING LIMIT SWITCH
(displayed only if
CF = 1)
Enables/disables the closing limit switches, to stop
the automation or start the slowdown. Modifying
the value requires a new SETUP.
no disabled
01 stop
02 start slowdown
no
So
INPUT EDGE1 CONFIGURATION
nc Sensitive edge with NC contact
1r 1 Resistive sensitive edge 8.2 k
2r 2 Resistive sensitive edges 8.2 k (Con-
nected in parallel)
nc
Sc
INPUT EDGE2 CONFIGURATION
nc Sensitive edge with NC contact
1r 1 Resistive sensitive edge 8.2 k
2r 2 Resistive sensitive edges 8.2 k (Con-
nected in parallel)
nc
Br
BRAKING FOR SLIDING GATE
(displayed only if
CF = 2)
00 braking disabled
0110 (levels; 10 =maximum braking)
05
Cd
LEAF CLOSING DELAY
(displayed only if
Mn = 2)
The delay is applied to MOTOR 1.
Displayed in seconds up to 59, then in steps of 10 s.
0059 (Adjustment step: 1 s)
1.01.3 (Adjustment step: 10 s)
05