Ventilate the space above the appliance (min. 1000 mm
2
);
Always supply the appliance with a DC convection set;
The plaster of the outside has to be resistant to a high temperature.
Use therefore the plaster materials especially made for this such as
Masterboard or Fibrelux, to prevent discolouring (min. 100 degrees
temperature resistant);
If the appliance is to be fitted against a wall with combustible
cladding, the cladding must be removed from the area covered by the
surround.
The minimum height from the top surface of the fire to the underside
of any shelf made from wood or other combustible materials is as
follows:
For a shelf up to 150 mm deep: Min. height of 350 mm (fig. 1).
If the shelf depth is greater than 150 mm add 50 mm to the shelf
clearance height for every 25 mm increase in shelf depth.
Side clearance = Minimum distance from the side of the fire frame to
combustible material = 150 mm.
On the next page you will find the dimensions of the appliances discussed
in this installation manual