Remote modules. RIO5, RIOW and RIOR series.
CNCelite
8058 8060
8065 8070
RIO5 REMOTE MODULES. (CANOPEN PROTOCOL).
3.
Digital inputs and digital outputs (double module).
ꞏ41ꞏ
REF. 2107
3.4.1 Elements (connectors).
Connector ꞏX8ꞏ & ꞏX9ꞏ & ꞏX12ꞏ & ꞏX13ꞏ. Digital outputs (8 outputs in each connector).
10-pin male Phoenix minicombicon contact (3.5 mm pitch). Both connectors must be
powered with 24 V DC and GND.
Connector ꞏX10ꞏ & ꞏX11ꞏ & ꞏX14ꞏ & ꞏX15ꞏ. Digital inputs (12 inputs in each connector).
12-pin male Phoenix minicombicon contact (3.5 mm pitch).
Signal. Function.
+ 24 V Power supply.
O17 - O48 Digital outputs.
GND Power supply.
X8
O17
+24V
GN D
O24
O18
O19
O20
O21
O22
O23
X12
O33
+24V
GN D
O40
O34
O35
O36
O37
O38
O39
X9
O25
+24V
GN D
O32
O26
O27
O28
O29
O30
O31
X13
O41
+24V
GN D
O48
O42
O43
O44
O45
O46
O47
Signal. Function.
I25 - I72 Digital inputs.
I36
I25
I60
I49
X10
I26
I27
I28
I29
I30
I31
I32
I33
I34
I35 I59
I58
I57
I56
I55
I54
I53
I52
I51
I50
X14
I48
I37
I72
I61
X11
I38
I39
I40
I41
I42
I43
I44
I45
I46
I47 I71
I70
I69
I68
I67
I66
I65
I64
I63
I62
X15