Remote modules. RIO5, RIOW and RIOR series.
CNCelite
8058 8060
8065 8070
4.
RIOW REMOTE MODULES. (CANOPEN PROTOCOL).
RIOW-2AI-PT100 module. Module of 2 inputs for PT100 temperature
sensors.
ꞏ78ꞏ
REF. 2107
4.11 RIOW-2AI-PT100 module. Module of 2 inputs for PT100
temperature sensors.
Expansion module with 2 analog inputs for PT100 temperature sensors. Each input has an
LED indicating the status of the bus an LED indicating a measuring error of the sensor.
48
15
26
37
C
A
D
B
RL signal of the sensor ꞏ1ꞏ
R- signal of the sensor ꞏ1ꞏ
Shield connection.
R+ signal of the sensor ꞏ1ꞏ
RL signal of the sensor ꞏ2ꞏ
R- signal of the sensor ꞏ2ꞏ
Shield connection.
R+ signal of the sensor ꞏ2ꞏ
Bus status indicator LED for
sensor ꞏ1ꞏ.
LED indicating an error at sensor
ꞏ1ꞏ; reading error or broken
cable.
Bus status indicator LED for
sensor ꞏ2ꞏ.
LED indicating an error at sensor
ꞏ2ꞏ; reading error or broken
cable.