2.8.3 Meter Mode
This mode widely used in cable pipe and other industrials where need
identify meters. There must be a shaft encoder.
The setting of this mode is as follow:
1. User the arrow keys to open Print menu.
2. If you want to use meter mode to print . You should set Print
Enable and Photocell Level menus.
a. Print Enable menu.
Figure2-26 . Print Control menu
●
Select Print Enable option.
● Set the Shaft Encode to Measure option.
●
If pec2 is connected, select Reset or Close.
● Set pulse per meter. For example, a 2000P/R shaft encoder,
the circumference is 250mm. There are 8000 pulses per meter. Set
8000 in Pulse per meter area.
● Set Print Internal in Print Length area. If Set 900, the
printer will print a message per 900mm.
b. Photocell Level menus.
Figure2-27 . Photocell Level Signal Block menus.
1,2. Set Photocell Levels high or low to allow the high or low activating
photocells.
3. Blocking Time set to avoid twice triggered for one product.