3.5.2. Additional remarks for time user field
Definition of Time User Field Code
1. Actual printing date and time = system current time + number of
days of Expiry term. If it is required to print the current time, the
Expiry term is set as 0."
2. In the printing information, the time user field size is determined
by the fonts selected during insertion."
3. When the "Print Form" is Data Matrix or QR Code, the "Width"
and "Height” shall be set according to the standard. For details,
see the section of preparation of QR code & bar code User Field."
Code
Definition
A
Monday to Sunday
BC
Year
DE
Month
FG
Day
HI
Hour
JK
Minute
LM
Second
OO
Week
PPP
Day
RR
Alpha Year Code
SSS
Alpha Month Code
T T
Alpha Day Code
U U
Alpha Hour Code
V V
Alpha Minute Code