Chapter 6 Description of Operations
PAGE 6-44
D-No.034 System Option 2 Standard setting: 000000
Optional functions of the controller are set here.
*****1: WORK change (0: Display panel/1: PLC I/O Signal)
Set to “1” if the change of WORK is to be performed from the external I/O (the change cannot be
performed from both the operation panel and the external I/O)
****1*: Reversing switch (0: Slide/1: Push Button)
Slide: P type, T type/Pushbutton: A type, S type
***1**: RS232C-1 output (0: PLC/1: Ethernet)
Not used.
**1***: NG result indication (0: enable/1: disable)
Set to “1” if the NG result indication is not to be performed.
*1****: Fieldbus Function Disable (0:OFF / 1: ON)
Set to “1” if Fieldbus is to be disabled with Fieldbus being installed.
1*****: WORK change priority (0: Fieldbus/1: standard I/O)
For selecting between using Fieldbus or the standard I/O when the change of WORK is to be
performed by the external I/O.
D-No.035 System Option 3 Standard setting: 000000
An optional function of the controller is set here.
*****1: Prohibit of Resume after Total Accept Relay (0: OFF./1: ON).
Set to “1” if restart is to be prohibited when the TOTAL-OK state is entered.
To cancel the prohibition, the RESET, STOP, or BYPASS input signal is set to ON.
The prohibition is not canceled even if batch reset is performed.
**1*** CW/CCW Change Select (0:IO input/1: Normal/Reverse switch)
Sets the operation when the IO input signal “START” turns ON by switching the Normal /Reverse
changeover switch of the tool to the reverse rotation mode.
0: Starts the fastening operation.
1: Starts the reverse rotation operation.
D-No.036 Gearhead Option Standard setting: 0, Setting range: 0 ~ 2
0: Standard head/1: Regular tube nut/2: Inverted tube nut
D-No.037 Ordinary Starting Switch Level Standard setting: 10, Setting range: 0 ~ 255
Please set 10.
D-No.038 High-speed Starting Switch Level Standard setting: 40, Setting range: 0 ~ 255
Please set 40.
*Please set 10 for the tool of D type.
D-No.039 Reversing Switch Level Standard setting: 10, Setting range: 0 ~ 255
Please set 10.
D-No.040~049 For Adjustment by the Manufacturer
Not used.