Chapter 4 Installation
PAGE 4-7
4-5-1 controller I/O Signals [BANK SELECT = OFF]
System parameter: SYS.033[xxx1xx] 0: 300ms/1: 800ms pulse length
Description of Function/Usage
Common input signal (bipolar)
When use this power supply, please use a shielding
line.Wire it from the noise source apart.
The fastening process is stopped when this signal is set to “OFF.”
Selection between A contact and B contact is possible.
System parameter: SYS.033[xx1xxx] 0: A contact/1: B contact
The fastening process is stopped and the fastening judgment of the
controller is cleared by inputting “ON.” (The ID data are cleared.)
While “ON” is input, the tool rotates in reverse and in accordance with
the selected WORK No.
While “ON” is input, the fastening process is started in accordance
with the selected WORK No. (“Deadman” specification).
The controller is put in the BYPASS (PROGRAM) mode while “ON” is
input.
When the START signal is set to “ON” while inputting “ON” into this
pin, the self-diagnosis of the torque transducer is not performed
before the start of the fastening operation (the start of tool rotation can
be shortened by approx. 60msec).
The WORK SELECT BIT 0 ~4 select signals enable selection
among parameter Nos. 1 ~ 32 by a combination of the 5 pin Nos.
Bank select signal (for WORK SELECT return signal)
Common output signal (bipolar)
Cycle counter (ACCEPT count) reset signal
Fastening Result
Data Available
Output when there are fastening result data in the controller.
Output when capacity of the CF card is less than 1%,
or CF card isnot inserted
Output when the fastening operation ends with a fastening result
falling outside a judgment range.
Output when the fastening operation ends with the fastening
results being within the judgment ranges.
Output when an error occurs in the system or during the
fastening operation.
Output when operation is enabled with respect to an input signal
from the outside. This signal is also output after the end of
fastening, regardless of the judgment.
Output during the fastening process.
Output when the controller is in the BYPASS (PROGRAM) mode.
Turns ON when manually starting the reversed operation.
Turns OFF when the next fastening starts or turns OFF at RESET,
PROGRAM. (Relay contact-1)
Performs interlocking output of REJECT signal ON/OFF to external
devices.
*However, the key click sound is not output. (Relay contact-2)
BATCH OK (RY3-1)
[TOTAL OK]
Output when the fastening results are OK for the cycle count times of
fastening (relay contact-3).
Selection between pulse and level outputs is possible.
System parameter: SYS.033[xxxx1x] 0: level/1: pulse
Relay contact-1, 2, 3 common
QL OK (RY4-1)
[OK] (RY4-2)
OK output for QL signal (dry contact) (Relay contact-4)
Selection between pulse and level outputs is possible.
System parameter: SYS.033[xxxxx1] 0: level/1: pulse