EasyManua.ls Logo

FEC HFC3000 - Page 40

FEC HFC3000
196 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Installation
PAGE 4-8
4-5-2 controller I/O Signals [BANK SELECT = ON]
The following output changes.
Pin No.
Signal
IN/OUT
Description of Function/Usage
TB1-12
BANK SELECT=[ON]
IN-12(NO)
Bank select signal (for WORK SELECT return signal)
TB3-7
WORK OUTPUT BIT 2
OUT-6(NO)
When BANK SELECT=[ON], return output of the select signals
of WORK SELECT BITS 2 and 3 is performed.
Note 1)
TB3-8
WORK OUTPUT BIT 3
OUT-7(NO)
TB2-1
WORK OUTPUT BIT 5
OUT-1(NO)
[ON] is output when any of 33 WORK to 64 WORK is selected.
TB2-2
NONE
OUT-2(NO)
[OFF] is output at all times.
TB2-3
NONE
OUT-3(NO)
TB2-4
WORK OUTPUT BIT 0
OUT-4(NO)
When BANK SELECT=[ON], return output of the select signals
of WORK SELECT BITS 0, 1, and 4 is performed.
Note 1)
TB2-5
WORK OUTPUT BIT 1
OUT-5(NO)
TB2-6
WORK OUTPUT BIT 4
OUT-12(NO)