Chapter 6 Description of Operations
PAGE 6-18
In the set value selection mode, “SYS.” is indicated in the WORK indication part in the case of a
system parameter and the parameter No. (01 to 64) is indicated in the WORK indication part in the case
of a fastening parameter.
The WORK indication part is changed by pressing the [►] or [◄] switch and the content of the data No.
is indicated accordingly.
When the [▲] switch is pressed when the last data No. of each parameter No. is indicated, the value
in the WORK indication part is incremented by 1.
Also, when the [▼] switch is pressed when the head data No. of each parameter No. is indicated, the
value in the WORK indication part is decremented by 1.
Also, the current cursor position can be moved by pressing the [►] or [◄] switch and, by long-pressing
the [▲] or [▼] switch, the value in the WORK indication part can be skipped by 5 at a time or the value in
the WORK indication part can be skipped by 10 at a time.
Please refer to the “List of Parameters” regarding the details of the set values.
WORK COUNT/D-No. DATA
Torque controller
Software Version
Amplifier Version
ID input selection
Fastening Method
Fastening Steps
Fastening Option
Sequence
Stage 8
0 0 1
0 0 0
P 0 1
0 0 2
5 0 3
S Y S
0 0 1
0 0 0
0 0 2
5 8 8
P 6 4
[▲] switch or [▼] switch
WORK indication part: skipping by 5 at a time
by long-pressing
COUNT/D-No. indication part: skipping by 10
at a time by long-pressing