Chapter 6 Description of Operations
PAGE 6-19
6-3-3 Indications in the PROGRAM Mode
Immediately after changing to the “Set Value Editing Mode,” the cursor (flashing number) is indicated
in the upper stage of the indication part. When the [▲] or [▼] switch is pressed, the numerical value
at the cursor position changes by ±1.
When the [◄] or [►] switch is pressed, the digit of the cursor position changes by ±1.
When the set value is edited and the [SET] switch is pressed, the set value is changed and changing
to the set value selection mode is performed. When the [RESET] switch is pressed in the “Set Value
Editing Mode,” changing to the set value selection mode is performed without changing the set value.
Also, when the changed set value is outside the setting range, the following is indicated and changing
to the set value selection mode is performed without changing the set value.
The changed parameter is effective when the PROGRAM mode switches to the RUN
mode, or when the PROGRAM signal changes from ON to OFF.
Turning the power OFF in the PROGRAM mode during the change returns to the
parameter before the change.
Set Value Editing Mode
Change of
Fastening
Parameter
SET
SET
SET
Caution