SS2000+ Hotkey Activation
Description, Specications, SSLoader + Software, and Operation Manual
Federal Signal www.fedsig.com
SS2000+ Hotkey Activation
The following section describes how to activate from the front panel hotkeys on the
SS2000+ unit.
Unlocking the System
The SS2000+ keypad is secured with a key lock switch. When the key is in the LOCK
position, the LCD displays Keypad Locked message, time, and date.
** Keypad Locked **
SS2000+
07:29 06/19/2019 (c)
When the key is turned to the UNLOCK position, the keypad is enabled and the standby
screen displays on the LCD. The unit is ready to accept commands.
Press Function Key
F1..F2 to Activate
07:29 06/19/2019 (c)
When the unit is powered up,
When the SS2000+ is on, the printer prints SS2000+ On Line.
Automatic Logging
The SS2000+ displays all incoming and outgoing message on the LCD display. If enabled
in the configuration, the SS2000+ logs any incoming statuses and alarms DTMF or Digital
to the printer. If Com Port 2 is configured for Printer Messages, the status and alarms are
sent there as well. Also, the SS2000+ logs each time it powered up, all manual encode
activations, outgoing poll requests, and the results of each step in the self test procedure.
The SS2000+ decodes and displays on the LCD any incoming DTMF of Digital status or
alarm messages. A typical message includes the site number, siren type, and alarm or
status depending on the message type.
Press Function Key
F1..F2 to Activate
Site# 001 FCD Alarm
07:29 06/19/2019 (s)