8 Mounting of the Transducers FLUXUS G80x
UMFLUXUS_G8V4-6-1EN, 2018-10-10 53
8.3.1 Disassembly of Variofix L
Disassemble the transducer mounting fixture Variofix L (see Fig. 8.5).
8.3.2 Fixing the Clasps to the Tension Straps
Select the installation instructions that correspond to the supplied clasp:
Band clamp clasp
The clasp is fixed to the tension strap (see Fig. 8.6).
Quick release clasp
The clasp is fixed to the tension strap (see Fig. 8.7).
Cut the tension straps to length (pipe circumference + at least 120 mm).
Ratchet clasp
Cut the tension strap to length (pipe circumference + at least 120 mm).
Insert approx. 100 mm of the tension strap into parts 1 and 2 of the clasp (see Fig. 8.8 a).
Bend the tension strap.
Insert the tension strap into part 1 of the ratchet clasp (see Fig. 8.8 b).
Tighten the tension strap.
Repeat the steps for the second tension strap.
Fig. 8.5: Disassembly of Variofix L
Fig. 8.6: Band clamp clasp
with tension strap
Fig. 8.7: Quick release clasp
with tension strap
Attention! The edge of the tension strap is very sharp, leading to risk of injury. Remove the burr of the sharp edge.
cover
rail
tension strap clamp
nut
screw