FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 107 of 170
12.1.1 Continuous Data Formats
RELATED PARAMETERS: Parameters 111, 121, 131, 141 and 151.
Continuous data output can be programmed to the same common formats besides Flintec continuous format.
To select one of the described formats below press the key sequentially. Press key to go to the
next parameter.
Flintec
®
Start of transmission character.
1 = Zeroed
with power
on zerp
Always 0 as ASCII ( 30 hex ).
These seven characters are a string containing the current weight not
including the decimal point.
These seven characters are a string containing the tare weight not
including the decimal point.
Checksum byte. Checksum calculation is;
CHK (Checksum) = 0 – ( STX + STATUS A + ..... + LF )
(1) Error Messages: UNDER, OVER, A.OUT, L-VOLT and TILT are represented in Indicated data fields
as left aligned.