FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 108 of 170
HBM
®
Z = Centre of zero,
O = Over cap,
U = Under cap,
E = Weight not currently being displayed.
“ “(space) = None of the above conditions.
Range.
1 = First range,
2 = Second range,
3 = Third range.
Mode.
G = Gross weight,
T = Tare weight,
N = Net weight,
g = Gross weight in increased resolution.
n = Net weight in increased resolution.
Motion.
M = Motion,
“ “(space) = No motion.
Always a space as ASCII ( 20 hex ).
These ten characters are a string containing the current weight including
the decimal point.
Unit of weight value are kg, g, lb, klb, N or kN as left aligned.
Carrige Return ( 0D hex )