FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 109 of 170
Rinstrum
®
Description
STX
Sign
Indicated weight
ST
ETX
Example
0
.
7
5
0
N
Avery
®
E1205
Description
STX
Indicated weight
SP
Unit
SP
ST
CR
LF
ETX
Example
0
.
7
5
0
k
g
N
Baster
®
Description
Indicated Weight
LF
Example
0
.
7
5
0
LM2
Character
number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Description
Indicated Weight
Unit
SP
NET
LF
CR
Example-1
0
.
7
5
0
K
g
N
E
T
L
F
C
R
Example-2
1
.
0
0
0
K
g
L
F
C
R
Function
Description
Indicated Weight
These eight characters are a string containing the current weight not
including the decimal point.
Unit
Unit of weight value are Kg, G, Lb, N or KN as left aligned.
SP
Only sent a space character in Net operation. Otherwise there is no any
character.
NET
These three characters are only sent in Net operation. Otherwise there is
no any character.
LF
Line Feed ( 0A hex )
CR
Carrige Return ( 0D hex )
Registered trademarks
Terms and product names mentioned in this publication are trademarks, registered trademarks or service
marks of their respective owners. Use of a term should not be regarded as affecting the validity of any
trademark, registered trademark or service mark.
HBM
®
is a registered trademark of Hottinger Baldwin Messtechnik.
TOLEDO
®
is a registered trademark of Mettler-Toledo.
SysTec
®
is a registered trademark of Systemtechnik und Industrieautomation.
Sartorious
®
is a registered trademark of Sartorious.
Rinstrum
®
is a registered trademark of Rinstrum.
Avery
®
is a registered trademark of Avery Weigh-Tronix.
Baster
®
is a registered trademark of Baster.