EasyManua.ls Logo

Flintec FT-112 - Page 115

Flintec FT-112
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 114 of 170
Start dynamic weighing
DD
DDA
Read dynamic weight
DR
DRA [8 digit Weight data]
Reset ( to basic weighing )
DE
DEA
Write preset tare and apply
DP+[8 digits PT data]
DPA
Read preset tare
DQ
DQA+[ 8 digit PT data ]
Write APW and apply
DM [ 12 digits APW data ]
DMA
Read APW
DN
DNA [ 12 digits APW data ]
Key lock / unlock
DL 1(0)
DLA
Print the label
DJ
DJA
Read the last printed data
DO
DOA [ single line data format]
Checksum Calculation:
CHK is transmitted as two ASCII characters calculated with the Checksum formulation.
Checksum = 0 (SUM of all response data before CHK)
Example: Read stable current weight data.
BSI Examples: (CHK is enabled and instrument address is 01)
Command: 01P[CHK][CR][LF]
Checksum
=
0 − (0x30 + 0x31 + 0x50)
=
0 − 0XB1
=
0x4F
=
Char ‘4’ and ‘F’
Response: 01PS+000123.4[CHK][CR][LF]
Checksum
=
0 − (0x30 + 0x31 + 0x50 + 0x53 + 0x2B + 0x30 + 0x30 + 0x30 + 0x31+ 0x32 + 0x33 +
0x2E + 0x34)
=
0 − 0x02B7
=
0x49
=
Char ‘4’ and Char ‘9