FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 167 of 170
- Press enter key and re-enter the
fieldbus setup.
- Change E
2
ROM (U13).
Setpoint (limit values) checksum
error.
- Press enter key and re-enter the
setpoint (limit) values.
- Change E
2
ROM (U13).
- Change CR2032 battery.
- Change the main board.
ID header checksum error.
- Change main board.
- Change E
2
ROM (U13).
Checksum error of EPL printout
format.
- Press enter key and re-load the EPL
code.
- Change E
2
ROM (U13).
ADC output is not changed for
the span calibration.
- Recalibrate the scale.
- Change mainboard.
The load cell output is decreased
after loading.
- Check load cell connections.
- Check test weight loading.
- Recalibrate the scale.
- Change mainboard.
The load is not enough for span
calibration.
The load is not stable at
calibration.
- Wait until scale become stable.
- Check grounding wiring.
- Recalibrate the scale.
- Change mainboard.
Alibi memory SD card is not
installed.
- Disable Alibi memory if not required.
- Check Alibi SD card.
- Change mainboard.
Alibi SD card has not been
supplied from FLINTEC.
- Install Flintec Alibi SD card.
Alibi memory serial number error.
The new alibi SD card is installed.
- Format the alibi memory SD
card. Refer to parameter 816.
Alibi memory could not be
initialized.
- Check alibi memory SD card
- Change main board.
- Check alibi memory records.
- Change Alibi memory SD card.
- Change main board.
Alibi information CSUM error.
Wrong SD card at alibi memory.
The DLC Board is broken or not
installed.
- Re-energize indicator.
- Change the DLC Board.
- Check data format of other interfaces.
- Other interfaces should not be
Modbus.
Tare range error at filling
- Check scale stability.
- Check tare min and max values.
Target value error at
checkweighing.
- Restart totalization after deleting
before total.
- Change E
2
PROM (U13).
- Change main board.
Totalization data cannot be
recorded to the alibi memory.
- Check alibi memory SD card.
- Change main board.
The Modbus SD card is not
installed in SD2 card slot.
- Order Modbus SD card.
- Install Flintec Modbus SD card.