FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 49 of 170
Default is 192.168.016.250
[
153
ADDRESS
:
01
]
Address of the port
00 …. 255.
00 means data format without address.
[
154
SUB MASK
:
000
]
Subnet mask address.
Default is 255.255.255.000
[
155
GATEWAY
:
253
]
Gateway address.
Default is 192.168.016.253
[
156
LOCAL P1
:
502
]
Local port 1.
000 …. 65535
[
157
LOCAL P2
:
503
]
Local port 2.
000 …. 65535
[
158
LOCAL P3
:
504
]
Local port 3.
000 …. 65535
[
159
DNS
:
222
]
DNS address.
Default is 208.067.222.222
[
15A
MAC ADR
:
]
MAC address.
AA:BB:CC:DD:EE:FF
[
15B
TIMEOUT
:
5
]
Inactivity time out.
00 means disable.
01…. 60 sec.
[
15C
CR-LF
:
YES
]
Carriage return and Line feed at continuous formats.
NO
YES
:
:
Disable
Enable
[
15D
DELAY
:
050
]
Data output delay at demand formats; delay between continuous
format data.
000 …. 999 milliseconds.
[
15E
REMOTEIP
:
000
]
Remote IP address.
Default is 0.0.0.0
[
15F
REMOTEPO
:
0
]
Remote port.
0 …. 65535
[
16-
PRINTER
]
PRINTER
Press key or key again to enter this menu.
Or press key to go to the next sub-block.
[
161
FORMAT
:
26F2
]
Data format of the printout
Page 91
SING
16F1
16F2
26F1
26F2
EPL
:
:
:
:
:
:
Single line
Multiline Format 1 for 16 Character printer
Multiline Format 2 for 16 Character printer
Multiline Format 1 for 26 Character printer
Multiline Format 2 for 26 Character printer
EPL Format