FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 51 of 170
Line feed after printout.
+ = Forward, - = Backward
NO,1,2….9 : Line feed quantity after data.
Example: -2 means 2-line feed backward.
Space from left of the label.
ANALOGUE OUTPUT (Only FT-112(D) AN)
Press key or key again to enter this menu.
Press key to return to beginning of the sub-block or press
key to enter the next main-block.
4 mA - 20 mA
0 mA - 20 mA
0 VDC- 10 VDC
0 VDC- 5 VDC
The minimum of the analogue output. Default 00.0 means the
minimum output is not drifted.
e.g. enter 1.0 to set output to 1.0 volt at 0 kg in 0 -10 V range.
The maximum of the analogue output. 00.0 means the maximum
output is not drifted.
e.g. enter 9.0 to set output to 9.0 volt at Max load in 0 -10 V range.
Source of the analogue output
Gross weight
Indicated weight
Displays the count value of unloaded scale.
Increase or decrease by pressing or ; or enter the value
by pressing numerical keys to change the unloaded scale output.
Displays the count value of the full loaded scale.
Increase or decrease by pressing or ; or enter the value
by pressing numerical keys to change the analogue output gain.
Set analogue output to calibration range
No
Automatic adjustment between min and
max limits if changed.