FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 55 of 170
Information data on the left of the alphanumeric display.
NO
TARE
GROS
ID1
ID2
TOTA
Q+TO
GTOT
No data
Tare weight is displayed
Gross weight is displayed in Net
ID1 Data
ID2 Data
Total
Quantity and total
Grand Total
Note: The par 221 is set to NO, if this parameter isn't programmed
NO, TARE or GROS.
START UP
Press key or key again to enter this menu.
Or press key to go to the next sub-block.
Disabled.
Tare with key, via serial interface or via digital input.
Tare with key, via serial interface or via digital input
only at gross.
Preset tare and tare with key or via serial interface.
Preset tare and tare with key or via serial interface at
gross.
Disabled.
Auto tare, if the gross load is bigger than MIN TARE
and stable.
Disabled.
Auto clear, if the gross load is lower than 10d.
Disabled.
Tare value is saved at power off and the indication is
start in NET after switch on the instrument.
NO
VLO
W
LOW
MEDI
HIGH
VHIG
Disable. Fastest weighing; but the most sensitive to
environmental vibrations.
Very low filtering
Low filter
Medium filter
High filter
Very high filter. Slowest and the most stable weighing.
English
Deutsch
Français
İtaliano
Espagnol
Türkçe
Net sign correction at displaying and printing.