EasyManuals Logo

FLIR E96 User Manual

FLIR E96
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
Working with measurement tools
12
12.1 General
To measure a temperature, you can use one or more measurement tools, e.g., a spot-
meter or a box.
12.2 Adding/removing measurement tools
Follow this procedure:
1. Push the navigation pad to display the menu system.
2. Select
(Measurement) and push the navigation pad. This displays a submenu.
3. Use the navigation pad to select one of the following:
Select
(No measurements) to remove all tools.
Select
(Center spot) to add a center spot.
Select
(Hot spot) to add a hot spot detection within a box area.
Select
(Cold spot) to add a cold spot detection within a box area.
Select (depending on the camera model)
(User preset 1) to add user preset 1
or
(3 spots) to add three spots.
Select (depending on the camera model)
(User preset 2) to add user preset 2
or
(Hot spot - Spot) to add a hot spot and a spot and display the temperature
difference.
4. Push the navigation pad to confirm and exit the menu mode.
12.3 Editing user presets
Note The availability of this feature is dependent on the camera model.
A user preset is a measurement tool, or a group of measurement tools, with predefined
characteristics.
Follow this procedure:
1. Push the navigation pad to display the menu system.
#T810587; r. AA/74078/74713; en-US
59

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR E96 and is the answer not in the manual?

FLIR E96 Specifications

General IconGeneral
Resolution640 × 480 pixels
Temperature Range-20°C to 1500°C (-4°F to 2732°F)
Field of View24° × 18°
Detector TypeUncooled microbolometer
Digital Camera5 MP
Wi-FiYes
Laser PointerYes
Image Frequency30 Hz
Accuracy±2°C (±3.6°F) or ±2% of reading
Digital Zoom1-8x continuous
Laser Distance MeterYes
Operating Temperature Range-15°C to 50°C (5°F to 122°F)
Storage Temperature Range-40°C to 70°C (-40°F to 158°F)
IP RatingIP54
Thermal Sensitivity<30 mK at 30 °C (86 °F)
Display4" LCD touchscreen
Storage MediaSD card
Battery TypeLi-ion battery
Minimum Focus Distance0.15 m (0.49 ft)
Spectral Range7.5 – 14 μm
Weight1.2 kg (2.7 lbs)