2.Installthe3xthreadedstudsintothebaseofthecamerawiththread-lockingcompound.
Ifrequired,youcanusestudsofadifferentlengthtosuityourinstallation.
3.Slidethefoamgasketoverthethreadedstuds,andstickitrmlyintoplaceonthe
camera’sbase.
4.Connectthepowersupplycable,BNCvideocableandnetworkcablestothecamera,
andthreadthecablesthroughthecentralhole.
5.Placethecameraonthemountingsurfacesothethreadedstudsextendthroughthe
drilledholes.
6.Maketherequiredconnectionswiththefreeendsofthecables.
7.Slideaatwasher,andthenaspringwasher,ontoeachstud.
8.Securethecamerabodytothemountingsurfacewiththesuppliednuts,ensuringthatthe
sealremainscorrectlypositionedonthecamera’sbase.
Tightenthenutstoatorqueof5.0N·m(3.7lbf·ft).
Domecappednutsareprovidedforaneatersolutionwherethemountingisexposedto
view.