EasyManua.ls Logo

FLIR ThermaCAM P65

FLIR ThermaCAM P65
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CommentsValueLabel
Move the joystick left/right to lock the temperature
scale to maximum temperature, minimum temper-
atur or a certain temperature span. After having
set Lock scale to Max, Min or Span you will need
to specify a temperature Lock value box.
Typical application for Max:
You are inspecting an object that is located in front
of a background with a considerably higher tem-
perature e.g. an object in a very hot furnace. In
this case you want to use as many colors as pos-
sible for your object and as few as possible for the
background. To do this, specify a temperature
slightly above the temperature you can expect for
your object.
Typical application for Min:
You are inspecting an object that is located in front
of a background with a considerably lower temper-
ature e.g. power lines in front of a clear sky. In
this case you want to use as many colors as pos-
sible for your object and as few as possible for the
background. To do this, specify a temperature
slightly below the temperature you can expect for
your object.
Typical application for Span:
You are inspecting an object where you are only
interested in a fixed temperature span e.g. a fixed
span of, say, 5 degrees for veterinary applications,
or 20 degrees for building applications. In this case
you can lock the span so that a span of 5 and 20
degrees, respectively, is always used and floats
freely around the object temperature.
Off
Max
Min
Span
Lock scale
Move the joystick left/right to specify a temperature
for Lock scale.
Lock value
Move the joystick left/right to enable or disable the
scale.
On
Off
Scale
Move the joystick left/right to enable or disable the
status bar.
On
Off
Status bar
10
114 Publ. No. 1557954 Rev. a155 ENGLISH (EN) February 7, 2006