16 Technical specifications &
dimensional drawings
➲ FLIR Systems reserves the right to discontinue models, parts and accessories, and
other items, or change specifications at any time without prior notice.
16.1 Imaging performance
1.3 mradSpatial resolution
± 2 °C/± 3.6 °F or ± 2 % of readingAccuracy
50/60 Hz, non-interlacedImage frequency
2x, 4x, 8x – interpolatingElectronic zoom function
Automatic or manualFocus
Adaptive digital noise reductionDigital image enhancement
640 × 480 pixels, full colorBuilt-in digital video
16.2 Detector
Focal Plane Array (FPA), uncooled microbolome-
ter,
320 × 240 pixels
Type
7.5–13 μmSpectral range
16.3 Image presentation
Built-in, high resolution color LCD (TFT)Viewfinder
4"LCD on remote control
16.4 Temperature ranges
Temperature range is subject to customer config-
uration, and/or three-digit camera type number.
Refer to the camera menu system to see available
temperature ranges.
Temperature range
16.5 Correction parameters
Set by number, or by selection in predefined listEmissivity correction
16
Publ. No. 1557954 Rev. a155 – ENGLISH (EN) – February 7, 2006 141