STRADA PAL – MAINTENANCE MANUAL
146/149
9.3 Exchangeable coin box failure code
In case of exchangeable coin box failure:
If the terminal is equipped with several means of payment, the collection failure
LEDs are green. Payment by coins is impossible, but payment by card is
available.
If payment by coins is the only means of payment available, the respective LEDs
are red.
Code
Failure message
Problem
Solution
9001
COMM. DEFAULT
MCB
Communication problem
between the CP and the coin
box.
Contact the technical
service.
9003
LOCK. DEFAULT MCB
The coin box cannot lock the
actuator.
Contact the technical
service.
9004
UNLOCK. DEFAULT
MCB
The coin box cannot unlock the
actuator.
Contact the technical
service.
9005
TM MCB DEFAULT
The coin box does is not
detected although the trapdoor
is closed.
End collection.
This failure is automatically
cancelled when a collection
ends correctly (coin box
present and trapdoor
closed).
9006
MCB SENSOR
DEFAULT
The coin box sensors are faulty.
Contact the technical
service.
9007
MCB TRAPDOOR
DEFAULT
The trapdoor is not closed.
Contact the technical
service.
9008
PROG. DEFAULT MCB
The coin box was not
programmed correctly.
Contact the technical
service.
9009
MCB FRAUD
DEFAULT
The coin box sensors have
changed states outside a
collection sequence; a fraud
attempt can be assumed.
Contact the technical
service.
900A
MCB COLLECTION
UNFINISHED
DEFAULT
The main board supply was cut
during a collection sequence.
Contact the technical
service.

Table of Contents