STRADA PAL – MAINTENANCE MANUAL
147/149
9.4 M1000/P1000 reader kit failure codes
LED off
Reader paired and
commissioned
Red LED blinking
Antiremoval sensor(s)
violated
Reader out of order.
check mounting.
do the commissioning (c.f. §3).
If the led is still blinking red after
reboot of the reader, return product to
factory for analysis with a “reader
antiremoval SWx issue” notice.
Red LED on
Tampering sensor(s)
violated
Reader deactivated.
Return product to factory for analysis
with a “internal sensor violated”
notice (please write which one is
violated)
Yellow LED blinking
Reader and possible
pinpad are not paired.
Process pairing even if there is no
pinpad in the machine
Yellow LED on
Anti-removal and / or
tampering sensors not
initialized. Reader is not
active.
Return product to factory for analysis
with a “reader not initialized” notice
White Led blinking
Certificat reader is KO
Set the date PnD and initialization
reader
If the LED reader still is white
blinking
Return product to factory for analysis
with a “reader not certified” notice