4 INSTALLATION
4.1 GENERAL DIRECTIONS
Mounting, electrical installation, start-up and maintenance of this instrument may only be
carried out by trained personnel authorized by the operator of the facility. Personnel must
read and understand this Operating Manual before carrying out its instructions.
The E115-P may only be operated by personnel who are authorized and trained by the
operator of the facility. All instructions in this manual are to be observed.
Ensure that the measuring system is correctly wired up according to the wiring diagrams.
Protection against accidental contact is no longer assured when the housing cover is
removed or the panel cabinet has been opened (danger from electrical shock). The
housing may only be opened by trained personnel.
Take careful notice of the “Safety rules, instructions and precautionary measures” at the
front of this manual.
4.2 INSTALLATION / SURROUNDING CONDITIONS
Take the relevant IP
classification of the casing
into account (see
manufactures plate). Even an
IP66 / IP67 / TYPE 4X casing
should NEVER be exposed to
strongly varying (weather)
conditions.
When used in very cold
surroundings or varying
climatic conditions, take the
necessary precautions
against moisture by placing a
dry sachet of silica gel, for
example, inside the
instrument case.
Mount the E115-P on a solid
structure to avoid vibrations.
Relative humidity:
< 90% RH
Outdoor use:
suitable for outdoor use
IP and NEMA rating:
IP66, IP67 and NEMA Type 4X
Supply voltage fluctuation:
+/- 10% unless stated otherwise
Means of protection:
Class I
Over-voltage category:
II
Pollution degree:
2 (internal environment), 3 (external environment)
Ambient temperature:
-40 °C to +70 °C, -40 °F to + 158 °F
Altitude:
up to 2000 m

Other manuals for Fluidwell E119-P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluidwell E119-P and is the answer not in the manual?

Fluidwell E119-P Specifications

General IconGeneral
BrandFluidwell
ModelE119-P
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals