EasyManuals Logo

Fluke 1652C User Manual

Fluke 1652C
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
1652C/1653B/1654B
Users Manual
ii
General Specifications ........................................................... 45
Category Ratings and Usage ................................................. 46
Electrical Measurement Specifications................................... 46
Insulation Resistance (R
ISO
)................................................ 46
Insulation Resistance (R
ISO
) (cont.) .................................... 47
Continuity (R
LO
)................................................................... 47
Loop Tests (Z
I
).................................................................... 48
RCD/FI Tests (
Δ
T, I
Δ
N)........................................................ 49
Earth Tests (R
E
).................................................................. 50
AC Voltage Measurement (V)............................................. 50
Continuity Testing (R
LO
) .................................................... 50
Insulation Resistance Measurement (R
ISO
)....................... 51
Loop and Line Impedance (Z
I
) ............................................ 52
No Trip and Hi Current Modes RCD/FI ............................... 52
Prospective Earth Fault Current Test (PSC/I
K
)....................... 52
RCD Testing........................................................................... 53
RCD Types Tested ............................................................. 53
Test Signals........................................................................ 53
Tripping Speed Test (
Δ
T).................................................... 54
Maximum Trip Time ............................................................ 54
RCD/FI-Tripping Current Measurement/Ramp Test (I
ΔN
). 55
Earth Resistance Test (R
E
)................................................... 55
Phase Sequence Indication.................................................... 56
Mains Wiring Test................................................................... 56
Operating Ranges and Uncertainties per EN 61557 .............. 57
Operating Uncertainties per EN 61557................................... 58

Table of Contents

Other manuals for Fluke 1652C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1652C and is the answer not in the manual?

Fluke 1652C Specifications

General IconGeneral
Test Voltage50 V, 100 V, 250 V, 500 V, 1000 V
Loop and Line Resistance0.01 Ω to 2000 Ω
RCD TestingYes
DisplayDigital
Frequency45 Hz to 65 Hz
Phase Sequence IndicatorYes
Power Supply6 x 1.5 V AA batteries
Weight1.2 kg
Voltage AC500 V
Voltage DC500 V
RCD Trip Current10 mA, 30 mA, 100 mA, 300 mA, 500 mA
RCD Trip Test1x
Safety StandardsEN 61010-1
Operating Temperature-10°C to +50°C
Earth Resistance TestNot available

Related product manuals