EasyManuals Logo

Fluke 1652C User Manual

Fluke 1652C
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
i
Table of Contents
Title Page
Introduction ................................................................................ 1
How to Contact Fluke ................................................................. 1
Safety ......................................................................................... 2
Unpacking the Tester ................................................................. 4
Operating the Tester .................................................................. 6
Using the Rotary Switch ......................................................... 6
Understanding the Pushbuttons.............................................. 7
Understanding the Display...................................................... 9
Input Terminals ....................................................................... 15
Using the IR Port .................................................................... 15
Error Codes ............................................................................ 16
Power-On Options .................................................................. 17
Making Measurements ............................................................... 19
Measuring Volts and Frequency ............................................. 19
Measuring Insulation Resistance............................................ 20
Measuring Continuity .............................................................. 21
Measuring Loop/Line Impedance............................................ 22
Loop Impedance (Line to Protective Earth L-PE) ................ 22
Earth Resistance Testing by Loop Method ......................... 25
Line Impedance................................................................... 26
Measuring RCD Tripping Time ............................................... 28
Measuring RCD Tripping Current ........................................... 32
RCD Testing in IT Systems .................................................... 34
Measuring Earth Resistance................................................... 34
Testing Phase Sequence........................................................ 36
Memory Mode ............................................................................ 37
Storing a Measurement .......................................................... 38
Recalling a Measurement ....................................................... 38
Clearing Memory .................................................................... 39
Uploading Test Results .............................................................. 40
Maintaining the Tester................................................................ 41
Cleaning ................................................................................. 41
Testing and Replacing the Batteries ....................................... 41
Testing the Fuse ..................................................................... 43
Specifications ............................................................................. 44
Features by Model .................................................................. 44

Table of Contents

Other manuals for Fluke 1652C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1652C and is the answer not in the manual?

Fluke 1652C Specifications

General IconGeneral
Test Voltage50 V, 100 V, 250 V, 500 V, 1000 V
Loop and Line Resistance0.01 Ω to 2000 Ω
RCD TestingYes
DisplayDigital
Frequency45 Hz to 65 Hz
Phase Sequence IndicatorYes
Power Supply6 x 1.5 V AA batteries
Weight1.2 kg
Voltage AC500 V
Voltage DC500 V
RCD Trip Current10 mA, 30 mA, 100 mA, 300 mA, 500 mA
RCD Trip Test1x
Safety StandardsEN 61010-1
Operating Temperature-10°C to +50°C
Earth Resistance TestNot available