EasyManuals Logo

Fluke 1652C User Manual

Fluke 1652C
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
v
List of Figures
Figure Title Page
1. Rotary Switch ............................................................................. 6
2. Pushbuttons ............................................................................... 7
3. Models 1652C and 1653B Display Features .............................. 9
4. Model 1654B Display Features .................................................. 10
5. Input Terminals........................................................................... 15
6. Error Display .............................................................................. 16
7. Lead Swapping Modes............................................................... 18
8. Volts Display/Switch and Terminal Settings ............................... 19
9. Insulation Resistance Display/Switch and Terminal Settings ..... 20
10. Continuity and Continuity Zero Display/Switch and
Terminal Settings ....................................................................... 21
11. Loop/Line Impedance/Switch and Terminal Settings.................. 22
12. Display After Zeroing.................................................................. 24
13. 3-Wire Connection for Earth Resistance Loop Test ................... 25
14. Line Impedance Display ............................................................. 26
15. Measuring in a 3-Phase System................................................. 27
16. RCD Tripping Time Display/Switch and Terminal Settings......... 28
17. RCD Tripping Current/Switch and Terminal Settings ................. 32
18. Connection for RCD Testing on IT Electrical Systems ............... 34
19. Earth Resistance Display/Switch and Terminal Settings ............ 34
20. Earth Resistance Test Connection ............................................. 35
21. Phase Sequence Display/Switch and Terminal Settings ............ 36
22. Phase Sequence Test Connection ............................................. 36
23. Attaching the IR Adapter ............................................................ 40
24. Replacing the Batteries .............................................................. 42

Table of Contents

Other manuals for Fluke 1652C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1652C and is the answer not in the manual?

Fluke 1652C Specifications

General IconGeneral
Test Voltage50 V, 100 V, 250 V, 500 V, 1000 V
Loop and Line Resistance0.01 Ω to 2000 Ω
RCD TestingYes
DisplayDigital
Frequency45 Hz to 65 Hz
Phase Sequence IndicatorYes
Power Supply6 x 1.5 V AA batteries
Weight1.2 kg
Voltage AC500 V
Voltage DC500 V
RCD Trip Current10 mA, 30 mA, 100 mA, 300 mA, 500 mA
RCD Trip Test1x
Safety StandardsEN 61010-1
Operating Temperature-10°C to +50°C
Earth Resistance TestNot available

Related product manuals