Fluke 190 Series II - Probe and Accessory Specifications

Fluke 190 Series II
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications
Meter Measurements for Fluke 190-xx2
8
119
Temperature (TEMP)
With Optional Temperature Probe
Ranges (°C or °F) ..................................-40.0 to +100.0 °
-100.0 to +250.0 °
-100.0 to +500.0 °
-100 to +1000 °
-100 to + 2500 °
Probe Sensitivity ............................ 1 mV/°C and 1 mV/°F
DC Voltage (VDC)
Ranges .....500.0 mV, 5.000 V, 50.00 V, 500.0 V, 1100 V
Full Scale Reading........................................5000 counts
Accuracy ............................................ ±(0.5 % +5 counts)
Normal Mode AC Rejection at 50 or 60 Hz ±1 % .... >60 dB
AC Voltage (VAC)
Ranges .....500.0 mV, 5.000 V, 50.00 V, 500.0 V, 1100 V
Full Scale Reading........................................5000 counts
Accuracy
15 Hz to 60 Hz ................................. ±(1 % +10 counts)
60 Hz to 1 kHz .............................. ±(2.5 % +15 counts)
For higher frequencies the frequency roll off of the
Meter input starts affecting accuracy.
Normal Mode DC Rejection .................................. >50 dB
AC+DC Voltage (True RMS)
Ranges......500.0 mV, 5.000 V, 50.00 V, 500.0 V, 1100 V
Full Scale Reading ........................................5000 counts
Accuracy
DC to 60 Hz...................................... ±(1 % +10 counts)
60 Hz to 1 kHz............................... ±(2.5 % +15 counts)
For higher frequencies the frequency roll off of the Meter
input starts affecting accuracy.
All accuracies are valid if the waveform amplitude is
larger than 5 % of full scale.
Amperes (AMP)
With Optional Current Probe or Current Shunt
Ranges............................. same as VDC, VAC, VAC+DC
Probe Sensitivity..................100 µV/A, 1 mV/A, 10 mV/A,
100 mV/A, 1 V/A, 10 V/A, and 100 V/A
Accuracy .......................... same as VDC, VAC, VAC+DC
(add current probe or current shunt accuracy)