Section
2
Operation
2-1.
INTRODUCTION
2-2,
This
section
describes how to
set
up and
make
measurements with your
Multimeter.
Even
though
you
may
have used
a
multimeter
before, we
recommend
that
you read the entire section
carefully
so that you
can use all
of the features of your Multimeter.
2-3.
SETTING UP
YOUR
INSTRUMENT
2-4,
Unpacking
2-5.
Your Multimeter
is
shipped
in a
special
protective
container that should prevent damage to
the instrument
during shipping. Check the shipping
order
against
the
contents
of the container
and report any
damage or
short
shipment
to the place
of
purchase
or the
nearest
Fluke
Technical Service Center.
A list of these
service
centers
is
located in Section 5. The container
should include
the
following:
The 8010A or 8012A Multimeter
Two test leads (one
red
and one black)
Line power cord
The 8010A/8012A Instruction
Manual
2-6.
If
reshipment
of
the
instrument is
necessary,
please
use the original shipping container. If
the
original
container is not available,
be sure
that
adequate
protection
is
provided to
prevent
damage
during
shipment. We
recommend
that the
instrument
be
surrounded
by
at least
three
inches of
shock-absorbing
material on
all sides
of
the
container.
2-7.
Remove the Multimeter from
its container
and
place
it
in
a convenient
location.
The carrying
handle on
the meter can
be
used
as
a prop-stand
or positioned
out of
the way (behind the Multimeter).
To position
the
handle,
pull
outward on the hubs of the handle
and rotate the
handle into position.
2-8,
AC
Line
Voltage
Requirements
2-9.
AC line
voltage requirements
for your Multimeter
are listed
on a decal attached
to the bottom
of the
instrument.
Refer
to Section
4 for the procedure
to
change the ac line
voltage
setting.
If your Multimeter
has
the
-
01
Battery
Option, refer
to
Section 6 for
information
on changing ac
line
voltages.
CAUTION
Do not connect
the power
cable
to the
instrument before
verifying that the
intended
source
matches the ac line
configuration
of
the instrument.
2-10.
Fuse Replacement
2-11.
There
is
one,
user-replaceable
fuse
(FI) in your
Multimeter. The
fuse
(FI) and the fuse
holder
form an
integral part of the
mA input connector and can
be
removed with ordinary
tools. The fuse
rating is:
2
A,
normal
blow
(recommended
part
AGX2).
2-12.
Use the following
procedure to replace the
fuse,
FI:
1. Set
the
POWER switch
to
OFF.
2.
Remove the
input power
cord
from the
Multimeter.
WARNING
DO NOT REPLACE
THE
FUSE WITH THE
INSTRUMENT
TURNED
ON OR CONNECT-
ED
TO LINE
POWER.
3.
Refer to
Figure
2-1,
item
5
for the location
of
the
fuse
holder.
2-1