EasyManua.ls Logo

Fluke SMFT-1000 - Page 43

Fluke SMFT-1000
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Multifunction PV Analyzer
Performance Tests
39
Table 14. AC/DC Power Test Points
Range
Frequency
[Hz]
552xA
Current
Output [A]
LCOMP
552xA
Config.
Te s t Po i n t s [ W ]
[W] [A] [V]
0 W to 100000 W
0 Vdc to 1000 Vdc
0 Vac to 700 Vac
1 A to 100 A
0
1NASingle-Wire51
5
3.8 NA 25-turn Coil 475 95
1NASingle-Wire101
10
3.8 NA 25-turn Coil 950 95
1NASingle-Wire501
50
3.8 NA 25-turn Coil 4750 95
1 NA Single-Wire 100 1
100
3.8 NA 25-turn Coil 9500 95
1 NA Single-Wire 500 1
500
3.8 NA 25-turn Coil 47500 95
1 NA Single-Wire 1000 1
1000
3.8 NA 25-turn Coil 95000 95
50
1 OFF Single-Wire 5 1
5
3.8 ON 25-turn Coil 475 95
1 OFF Single-Wire 10 1
10
3.8 ON 25-turn Coil 950 95
1 OFF Single-Wire 50 1
50
3.8 ON 25-turn Coil 4750 95
1 OFF Single-Wire 100 1
100
3.8 ON 25-turn Coil 9500 95
1 OFF Single-Wire 500 1
500
3.8 ON 25-turn Coil 4750 95
1 OFF Single-Wire 700 1
700
3.8 ON 25-turn Coil 66500 95

Other manuals for Fluke SMFT-1000