Foundry Hardware Installation Guide for the FES, FESX, and FWSX
7 - 4 © 2008 Foundry Networks, Inc. December 2008
Regulatory Compliance
Table 7.3 lists the Electromagnetic Compatibility (EMC), Immunity standards, and safety agency approvals for the
FastIron family of switches.
Power Source Interruptions
Table 7.4 shows how the FastIron compact switch protects against power surges and power drops.
Mean Time Between Failure
Table 7.5 lists the Mean Time Between Failure (MTBF) for the FastIron compact switches. The MTBF is the
average estimated time, in units of hours, before a hardware failure may occur.
Table 7.3: Regulatory Compliance
Certifications
Emissions:
CISPR-22 Class A
EN 55022
FCC Class A
VCCI Class A
Electromagnetic:
Generic: EN 50082-1
Table 7.4: Power Surge and Drop Protection
Property Protection Mechanism
Power surge MOV and Spark Gap protection
Power drop (<=1 second) An AC loss of >15ms will cause the
power supply to shut down due to
input under-voltage
Maximum power draw 195 watts with 2-port 10-Gigabit
uplinks
110 watts without 2-port 10-Gigabit
uplinks