Franking imprint is lopsided. Letters are not running sufficiently tightly along
the letter running edge through the mailing
system.
Set the adjustment wheel to a higher setting
(see page 32).
Letters are running lopsided through the
mailing system.
Use the letter guide on the Ramp plus
(see page 37).
Franking imprint is cropped too
tightly at the letter top edge / top.
Letters are not running sufficiently tightly along
the letter running edge through the mailing
system.
Set the adjustment wheel to a higher setting
(see page 32).
Crease formation when sealing
the envelopes.
Set the adjustment wheel to 1 or lower
(see page 32).
Separation error. Certain letter types (e.g. thin ISO C4 letters /
US9x12) may cause problems with separation.
In such cases, lay the stack ‘staggered’ in the
running direction of the letters (see page 37).
when weighing (Dynamic Scale)
Dynamic Scale captures no
weight.
Weighing function and format detection are
turned off.
To activate the ‘dynamic weighing’ function
please read chapter 4.3.
Scale is defective.
If you work without a scale, you will need to
manually enter the weight in the product
calculation menu.
Problem Possible cause and remedy