WALL MOUNT GAS-FIRED WATER BOILER — Boiler Manual
32 Troubleshooting(continued)
Figure 114#ONlGURATIONMODEFORFreeStyle
®
BOILERS0ARAMETERS$ESCRIPTIONS$EFAULTDISPLAYSAND.OTES
Parameter Description Default Note
b01 0
b02
(120Vac 3 way valve))
2 - Heating Only
3 - Combi
b03 0
b04 Fan absolute DHW maximum speed (Hz)
See Figure 119,
page 93.
DHW conf. dependent
b05 Fan absolute CH maximum speed (Hz)
See Figure 119,
page 93.
b06 Fan absolute minimum speed (Hz)
See Figure 119,
page 93.
b07
100
--
100
--
DHW conf. dependent
b08
60
--
60
--
DHW conf. dependent
b09 Fan offset low level (Hz) 10
b10 1
b11 Variable input switch functionality (Number) 4
b12 Variable output relay functionality (Number) 0
b13 External pcb variable output relay functionality (Number) 7
b14 24
b15 0
b16 Maximum exhaust gases temperature (°F) 185 PVC/CPVC sel. dependent
b17 1
b18
15
--
--
--
DHW conf. dependent
b19
0
0
0
0
DHW conf. dependent
b20 1
b21 Pump protection time (Sec) 5
b22 PVC/CPVC Selection 1
b23 PVC maximum temperature (°F) 176
b24 CPVC maximum temperature (°F) 185
b25 Pre-purge time between A01 attempts 0
b26 High altitude & Chimney length selection 0
b27
--
0
--
--
DHW conf. dependent
b28 20
Configuration mode
"YPRESSINGTHE$(7AND$(7PUSHBUTTONSTOGETHERFORSECONDSITISPOSSIBLETOENTERINTOTHE#ONlGURATIONMODE
The display starts with showing “BvBLINKING"YMEANSOFTHE#(hvAND#(hvPUSHBUTTONSIT ISPOSSIBLETOSELECTTHE
parameters; between “B” and “b28v3ELECTINGONEOFTHESEPARAMETERSBYMEANSOFTHE$(7hvAND$(7hvPUSHBUTTONS
it is possible to adjust his value (not flashing). The value is automatically saved.
"YPRESSINGTHE$(7AND$(7PUSHBUTTONSTOGETHERFORSECONDSITISPOSSIBLETOLEAVETHE#ONlGURATIONMODE
)FNOACTIONHASBEENTAKENTHE--)AUTOMATICALLYLEAVESTHISMODEAFTERMINUTES