QUANTUM™ COMPRESSOR CONTROL PANEL S90-010 M
MAINTENANCE Page 17
DIGITAL I/O BOARD #2 PICTORIAL
OUT
OUT
+5 VOLTS
+12 VOLTS
-12 VOLTS
GND
-RX / -TX
+RX / +TX
BOARD DC POWER
I/O
COMMUNICATIONS
DIPSWITCH SETTINGS SIGNIFY
BOARD IDENTIFICATION NUMBER
IN
PART # 640D0062H
F7
FUSE TESTER
M7
D7
M6
D6
D5
D4
D3
D2
TEST FUSE HERE.
IF LAMP LIGHTS
FUSE IS OK
SPARE FUSE
M23
D23
M22
D22
M21
D21
BOARD REVISION LEVEL
BOARD PART NUMBER
5A
OUT
IN
F24
M24
OUTPUT MODULE
OPTIONAL
D24
OUTPUT MODULE
OPTIONAL
OUTPUT MODULE
OPTIONAL
5A
F21
OUTPUT MODULE
OPTIONAL
P8
1
AMP794068-1
M19
D19
M18
D18
M17
D17
M16
D16
M15
D15
M14
D14
DIGITAL I/O BOARD #2
PART # 640D0062H01
REPLACEMENT PART # 640C0024G02
SERIAL #
REVISION
COMMUNICATIONS JUMPERS
Frick
*
OUTPUT MODULE
OPTIONAL
OUTPUT MODULE
OPTIONAL
INPUT MODULE
OPTIONAL
OUTPUT MODULE
OPTIONAL
INPUT MODULE
OPTIONAL
INPUT MODULE
OPTIONAL
D28
ACTIVE
MICROPROCESSOR
WATCHDOG LAMP
(BLINKS IF OK)
1
OPEN
J5
DP1
J7
J8
J9
J10
PROGRAM EPROM
I/O COMMUNICATION
ACTIVITY LAMPS
D25
TX
D26
RX
DIO
19200
PROGRAM VERSION
U8
1
AMP794068-1
5A
FUSE
SPARE
FUSE
D27
READY TO RUN
REMOTE ENABLE
HOT
NEUTRAL
REMOTE RUN/START/STOP
REMOTE LOAD
REMOTE UNLOAD
CPR MOTOR ON RE-CYCLE DELAY
HOT
NEUTRAL
SLIDE VALVE SETPOINT #1
SLIDE VALVE SETPOINT #2
AUX #3 PROGRAMMABLE
SHUTDOWN OR ALARM
AUX #4 PROGRAMMABLE
SHUTDOWN OR ALARM
HOT
NEUTRAL
AUX #5 PROGRAMMABLE
SHUTDOWN OR ALARM
AUX #6 PROGRAMMABLE
SHUTDOWN OR ALARM
AUX #7 PROGRAMMABLE
SHUTDOWN OR ALARM
AUX #8 PROGRAMMABLE
SHUTDOWN OR ALARM
HOT
NEUTRAL
OIL PUMP #2 STARTER
OIL PUMP #2 AUX
PERMISSIVE START
MAIN OIL INJ DISCHARGE TEMP
HOT
NEUTRAL
DX CIRCUIT #1
DX CIRCUIT #2
CONDENSER CONTROL #1
CONDENSER CONTROL #2
HOT
NEUTRAL
CONDENSER CONTROL #3
CONDENSER CONTROL #4
1
INPUT MODULE
OPTIONAL
OUTPUT MODULE
OPTIONAL
1
P4
5A
OUT
F14
INPUT MODULE
OPTIONAL
INPUT MODULE
OPTIONAL
5A
OUT
F13
M13
INPUT MODULE
OPTIONAL
D13
IN
INPUT MODULE
OPTIONAL
IN
OUTPUT MODULE
OPTIONAL
OUTPUT MODULE
OPTIONAL
OUTPUT MODULE
OPTIONAL
F17
5A
F16
5A
F15
OUT
IN
OUT
INPUT MODULE
OPTIONAL
IN
P5
5A
F19
5A
F18
5A
OUT
IN
OUT
IN
5A
F20
M20
D20
1
P6
5A
OUT
IN
F23
5A
OUT
IN
F22
OUT
IN
OUT
IN
OUT
IN
M5M4
M3M2
+5 DC
POWER
IS OK
P7
IN
OUT
5A
F3
1
P1
5A
F2
NOTE: OPTIONAL MODULES
INSTALLED WITH PURCHASED
OPTION
INSTALLED
FUSE
OUTPUT MODULE
POWER
ON
FUSE POSITION DETERMINES
INPUT OR OUTPUT
IN = INPUT OR UPPER LOCATION
OUT = OUTPUT OR LOWER LOCATION
5A
OUT
F1
M1
OUTPUT MODULE
OPTIONAL
D1
D29
INPUT MODULE
OUT
IN
OUT
IN
5A
F12
M12
D12
OUT
INPUT MODULE
OPTIONAL
OUT
IN
5A
F11
M11
D11
INPUT MODULE
OPTIONAL
5A
F10
M10
D10
5A
F9
M9
D9
5A
OUT
IN
F8
M8
OUTPUT MODULE
OPTIONAL
D8
OUT
IN
5A
OUT
IN
P2
5A
OUT
IN
F6
5A
F5
5A
OUT
F4
IN
1
P3
1
OUT
IN
IN