Page #10 background image
10 PB
SPECIFICATIONS
Refrigeration Systems Performance Data
Conden-
sor Temp
Deg. F
Discharge
Temp
Deg F
Suction
Temp
Deg F
Electrical Ratings
R-410A
REF. Breaker
Model
AMPS
COOL
AMPS
HEAT
LOCKED
ROTOR
AMPS
CHARGE
IN OZ Volt age
60
HERTZ
AMPS
Kühl
®
(Cool Only)
KCQ06A10A 119 148 55 4.8 25.2 18.8
115 15
KCQ08A10A 116 150 56 6.5 30.5 15.2 115 15
KCQ10A10A 119 161 52 8.6 49 19.4
115 15
Kühl
®
+ (Electric Heat)
KEQ0811A 114 145 48 6.4 11.2 30.5 15.6 115 15
*Rating Conditions: 80 degrees F, room air temp. & 50% relative humidity, with 95 degree F, outside air temp & 40% relative humidity, all systems use R-410A.
Test done at highest unit fan speed.
Figure 201 (Refrigeration Systems Performance Data)
Model UPC
Cooling
Btu
Heating
Btu Volts
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts EER CEER
Moisture
Removal-
Pints/HR CFM Sleeve
Kühl
®
(Cool Only)
KCQ06A10A 724587436570 6000 115 4.8 492 12.2 12.1 1.5 190
Q
KCQ08A10A 724587436587 8000 115 6.5 661 12.1 12.0 2.1 200
KCQ10A10A 724587436594 9500 115 8.6 864 11.0 10.9 3.2 250
Kühl
®
+ (Electric Heat)
KEQ08A11A 724587432749 7700 4000 115 6.4 694 11.2 1290 11.1 11.0 2.1 200
Q
Figure 202 (Specications)