12 PB
SPECIFICATIONS
Electrical Data
WARNING
ELECTRIC SHOCK HAZARD
Turn off electric power before service or
installation.
All electrical connections and wiring MUST be
the National Electrical Code and all local codes
which have jurisdiction.
Failure to do so can result in personal injury or
death.
NOTICE
FIRE HAZARD
electically unsafe conditions which could cause moderate
or serious property damage.
Read, understand and follow the above warning.
Circuit Rating/ Breaker/ power cord/ wall Receptacle
Model
CircuitRating
Breakeror
T-D Fuse
PlugFace
(NEMA#)
Power Cord
Length(ft.)
Required Wall
Receptacle
NEMANO.
Wall Outlet
Appearance
KCQ06A10A, KCQ08A10A,
KCQ10A10A, KEQ08A11A
125V-15A 5-15P 6
5-15R
Wire Size-UseONLYwiringsizerecommendedforsingleoutletbranchcircuit.
Fuse/ Circuit Breaker-UseONLYthecorrectHACRtypeandsizefuse/circuitbreaker.Readelectricalratingson
unit’sratingplate.Propercircuitprotectionistheresponsibiityofthehomeowner.
Grounding-UnitMUSTbegroundedfrombranchcircuitthroughservicecordtounit,orthroughseparateground
wireprovidedonpermanentlyconnectedunits.Besurethatbranchcircuitorgeneralpurposeoutletisgrounded.
Receptacle -Theeldsuppliedoutletmustmatchplugonservicecordandbewithinreachofservicecord.Do
NOTaltertheservicecordorplug.DoNOTuseanextensioncord.Refertothetableaboveforproperreceptacle
andfusetype.
Figure 205 (Circuit Breaker / Plug / Receptacle / Cord Rating)