OPERATION
Component Identication
EEV Control
The Electronic Expansion Valve is used to maintain
superheat during both cooling and heat pump operation.
Superheat (cooling) = Compressor Suction (T3) IDC
Cool Inlet (T1)
Superheat (heat pump) = Compressor Suction (T3)
ODC Heat Inlet (T7)
The EEV will open if the super heat is too high and will
meter if the super heat is too low.