146
Example:
- MIG/MAG welding process... e.g. use of a water-cooled welding torch: C-C = AUT
- TIG welding process... e.g. use of a gas-cooled welding torch: C-C = OFF
NOTE! Parameter C-C can be set differently for MIG/MAG welding and TIG weld-
ing.
C-t
Cooling time – time from when the flow watchdog is triggered until the "no | H2O" service
code is output. For example, if there are air bubbles in the cooling system, the cooling unit
will not cut out until the end of this pre-set time.
Unit s
Setting range 5 - 25
Factory setting 10
NOTE! Every time the power source is switched on, the cooling unit carries out a
test run for 180 seconds.
Stc
Wire-stick control
Unit -
Setting range OFF, ON
Factory setting OFF
The parameters for the wire-stick function (Stc) are available when a robot interface or
field bus coupler for robot control is connected to the LocalNet.
The wire-stick control function (Stc) is described in the "Robot welding" section.
Ito
Ignition time-out - Length of wire that is fed before the safety cut-out is triggered
Unit mm in.
Setting range OFF or 5 - 100 OFF or 0.20 - 3.94
Factory setting OFF
NOTE! The "Ignition time-out" function (ito) is a safety function. The length of wire
that is fed before the safety cut-out trips may differ from the pre-set wire length,
particularly when the wire is being fed at fast wire feed speeds.
The “Ignition time-out” function (ito) is explained in the “Special functions and options”
section.
Arc
Arc - Arc break watchdog
Unit s
Setting range OFF (arc break watchdog is deactivated);
0.01 - 2 (arc break watchdog is activated)
Factory setting OFF
The “Arc break watchdog” function (Arc) is explained in the “Special functions and op-
tions” section.
FCO
Feeder control - Wire-feed unit cut-out (wire end sensor option)
Unit -
Setting range OFF/ON/noE
Factory setting OFF

Table of Contents

Other manuals for Fronius CMT 4000 Advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius CMT 4000 Advanced and is the answer not in the manual?

Fronius CMT 4000 Advanced Specifications

General IconGeneral
BrandFronius
ModelCMT 4000 Advanced
CategoryAC Power Distribution
LanguageEnglish

Related product manuals