OFF: The power source halts wire feed when the wire end sensor is triggered.
"Err|056“ appears on the display.
ON: The power sources halts wire feed after completion of the current weld seam
when the wire-end sensor is triggered. "Err|056" appears on the display.
Acknowledge Err | 056
Insert a new wirespool and feed the wire electrode into the hosepack
noE: The power source does not halt wire feed when the wire end sensor is triggered.
The wire end alarm is not displayed and is only transmitted to the robot control
via the field bus.
NOTE! The "noE" setting only functions in conjunction with the field bus applica-
tions. Robot interfaces ROB 4000/5000 do not support this function.
SEt
Setting - Country-specific setting (Standard/USA)... Std/US
Unit -
Setting range Std, US (Standard/USA)
Factory setting Standard version: Std (measurements: cm/mm)
USA version: US (measurements in inches)
S4t
Special 4-step - Gun trigger (option)
Switch between jobs using torch trigger
Unit -
Setting range 0, 1 (Off, On)
Factory setting 1
Gun
Gun (welding torch) - Changing between modes with the JobMaster torch (optional)
Unit -
Setting range 0, 1 (Off, On)
Factory setting 1
NOTE! The “Gun Trigger” (S4t) and “Changing between modes with the JobMas-
ter welding torch” (Gun) options are explained in more detail in the “GunTrigger”
operating instructions.
S2t
Special 2-step (US control panel only) - for selecting jobs and groups by pressing the
torch trigger
Press once (< 0.5 s)... next job in a group is selected
Press twice (< 0.5 s)... next group is selected
r
r (resistance) - Welding circuit resistance (in m)
see "Measuring welding circuit resistance r"
L
L (inductivity) - Welding circuit inductivity (in microhenry)
see "Displaying welding circuit inductivity L"
COr
Correction - Gas correction ("Digital gas control" option)
Unit -
Setting range AUT/1.0 - 10.0
Factory setting AUT

Table of Contents

Other manuals for Fronius CMT 4000 Advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius CMT 4000 Advanced and is the answer not in the manual?

Fronius CMT 4000 Advanced Specifications

General IconGeneral
BrandFronius
ModelCMT 4000 Advanced
CategoryAC Power Distribution
LanguageEnglish

Related product manuals