54
A list of most status codes, the corresponding status information, their status causes and
repair measures can be found in the chapter "Troubleshooting and Maintenance," section
"Status Diagnosis and Troubleshooting."
Flashes orange A warning is shown on the display
or
the inverter has been set to standby operation in the Setup
menu (= manual shutoff of operation).
The next day, operation will resume automatically.
During the time the LED flashes orange, operation can be re-
sumed manually at any time (see section "The Setup Menu")
Steady red General status: the respective status code is shown on the
screen
Remains dark There is no connection to the solar modules,
no solar module power due to darkness.
GFDI Status LED
(B)
Explanation
remains dark there is no ground fault in the PV system;
the system is working properly
lights up red - a ground fault is detected and the GFDI fuse is blown
- the inverter does not feed energy to the grid
- the ground fault needs to be removed and the GFDI fuse
needs to be changed
(see section "Ground fault indication" in the chapter "Status
Diagnosis and Troubleshooting")
Operating Status LED
(A)
Explanation