48
External communication (Solar Net) takes place in the inverter via the data communication
rack. The data communication rack is equipped with two RS 422 interfaces - an input and
an output.
RJ45 plug connectors are used to establish the connection.
Maximum output
current for data
communication
and the 12 V sig-
naling output
The maximum total output current for data communication and the 12 V signaling output is
500 mA, which can be divided up as follows:
For more information about DATCOM components, see the "DATCOM Detail" operating
instructions.
Connecting data
communication
cables to invert-
ers
Data communication 200 mA 500 mA
12 V signaling output + 300 mA + 0 mA
Total 500 mA 500 mA
1
1
2
3
5x
2
IMPORTANTWhen networking several
DATCOM components, a terminating plug
must be placed on each free IN or OUT
connection of a DATCOM component.
IMPORTANT Close any unused openings
at the sealing insert using the appropriate
blanking plugs.
3
3
1
2
3