74
Yield Setting
- an OFFSET value for the Total energy display
- a measurement correction value for the day, year and total energy display
Energy Meter Offset
Specification of a value for the energy supplied that is added to the currently supplied en-
ergy (e.g., the transfer value when an inverter is replaced)
Energy Meter Unit
Assignment of the SI prefix (k..., M...)
Meter Calibration
Specification of a correction value so that the data shown on the inverter display corre-
spond to the calibrated data shown on the electric meter
Inverter Number Number setting (address) of the inverter in a setup where multiple solar inverters are linked
together
Setting range Energy Meter Offset / Energy Meter Unit / Meter Calibration
Unit Wh
Setting range 5-digit
Factory setting 0
Unit -
Setting range k / M
Factory setting -
Unit %
Setting range -5,0 - +5,0
Factory setting 0
Unit -
Setting range 00 - 99 (00 = 100. inverter)
Factory setting 01
IMPORTANT! Each inverter must be assigned its own address when using multiple invert-
ers in a data communications system.